<feed xmlns="http://www.w3.org/2005/Atom"><id>tag:powertech.blog.co.uk,2009-11-10:/</id><title>Electrical power systems</title><link rel="self" href="http://powertech.blog.co.uk/feed/atom/posts/"/><link rel="alternate" type="text/html" href="http://powertech.blog.co.uk/"/><generator version="1.0">MokoFeed</generator><updated>2009-11-10T12:19:26+01:00</updated><entry><id>tag:powertech.blog.co.uk,2007-06-23:/2007/06/23/short_transmission_lines_phaser_diagrams~2505091/</id><title>Short transmission lines: phaser diagrams</title><link rel="alternate" type="text/html" href="http://powertech.blog.co.uk/2007/06/23/short_transmission_lines_phaser_diagrams~2505091/"/><author><name>powerzone</name></author><published>2007-06-23T13:42:59+02:00</published><updated>2007-06-24T11:30:16+02:00</updated><content type="html">	&lt;p class="MsoNormal"&gt;&lt;strong&gt;&lt;u&gt;Short transmission lines:&lt;/u&gt;&lt;br&gt;&lt;/strong&gt;&lt;/p&gt;
	&lt;p class="MsoNormal"&gt;&lt;img src="http://data4.blog.de/media/032/1719032_8195caa2f6_m.jpeg" alt="shortline2" hspace="5" vspace="5" width="384" height="105"&gt;&lt;/p&gt;
	&lt;p class="MsoNormal"&gt;&lt;strong&gt;&lt;br&gt;&lt;/strong&gt;&lt;/p&gt;
	&lt;p class="MsoNormal"&gt;&lt;strong&gt;&lt;br&gt;&lt;/strong&gt;&lt;/p&gt;
	&lt;p class="MsoNormal"&gt;&lt;strong&gt;Here sending current is equal to receiving current .But sending &amp; receiving voltages are not equal to due to impedance voltage drop in the transmission line.&lt;/strong&gt;&lt;/p&gt;
	&lt;p class="MsoNormal"&gt;&lt;strong&gt;Vs=Vr+IZ&lt;/strong&gt;&lt;/p&gt;
	&lt;p class="MsoNormal"&gt;&lt;strong&gt;Receiving end voltage lag by &lt;/strong&gt;&lt;strong&gt;&lt;span&gt;&lt;/span&gt; angle with respect to sending end voltage. In practical situation step-up and step &amp;ndash;down transformer is used at sending end and receiving end of the transmission line as below.&lt;/strong&gt;&lt;/p&gt;
  &lt;br&gt;&lt;img src="http://data4.blog.de/media/031/1719031_98fe511142_m.jpeg" alt="shotline1" hspace="5" vspace="5" width="383" height="111"&gt;&lt;/p&gt;
	&lt;p class="MsoNormal"&gt;&lt;strong&gt;Therefore total impedance can be implemented as Z=Z&lt;sub&gt;T1&lt;/sub&gt;+Z&lt;sub&gt;L&lt;/sub&gt;+Z&lt;sub&gt;T2&lt;/sub&gt;&lt;/strong&gt;&lt;/p&gt;
	&lt;p class="MsoNormal"&gt;&lt;strong&gt;This can be equivalent to single phase circuit as below and transformer impedance can be assumed as series impedance.&lt;/strong&gt;&lt;/p&gt;
  &lt;img src="http://data4.blog.de/media/033/1719033_5d488dfb5f_m.jpeg" alt="shortline3" hspace="5" vspace="5" width="364" height="159"&gt;&lt;/p&gt;
	&lt;p&gt;&lt;br&gt;
&lt;a href="http://www.addthis.com/feed.php?pub=gayanefac&amp;h1=http%3A%2F%2Fgeneralpower.blogspot.com%2F&amp;t1=" title="Subscribe using any feed reader!"&gt;&lt;img src="http://s9.addthis.com/button1-fd.gif" width="125" height="16" border="0" alt="AddThis Feed Button"&gt;&lt;/a&gt;&lt;br&gt;
&lt;/p&gt;
&lt;p&gt; &lt;small&gt; &lt;a href="http://powertech.blog.co.uk/2007/06/23/short_transmission_lines_phaser_diagrams~2505091/#comments"&gt;Comments&lt;/a&gt; &lt;/small&gt; &lt;/p&gt;</content></entry><entry><id>tag:powertech.blog.co.uk,2007-06-18:/2007/06/18/google_analytic~2472100/</id><title>google analytic</title><link rel="alternate" type="text/html" href="http://powertech.blog.co.uk/2007/06/18/google_analytic~2472100/"/><author><name>powerzone</name></author><published>2007-06-18T05:47:16+02:00</published><updated>2007-06-18T05:47:16+02:00</updated><content type="html">	&lt;p&gt;google analytic is a another way of tracking your web site statistics. It shows the country , network , location , no of views, etc who came to your site.&lt;br&gt;

&lt;br&gt;

_uacct = "UA-1944987-3";
urchinTracker();

&lt;/p&gt;
&lt;p&gt; &lt;small&gt; &lt;a href="http://powertech.blog.co.uk/2007/06/18/google_analytic~2472100/#comments"&gt;Comments&lt;/a&gt; &lt;/small&gt; &lt;/p&gt;</content></entry><entry><id>tag:powertech.blog.co.uk,2007-06-17:/2007/06/17/page_rank~2470650/</id><title>page rank</title><link rel="alternate" type="text/html" href="http://powertech.blog.co.uk/2007/06/17/page_rank~2470650/"/><author><name>powerzone</name></author><published>2007-06-17T20:24:38+02:00</published><updated>2007-06-17T20:24:38+02:00</updated><content type="html">	&lt;p&gt;page rank buttons will display your site rank on web!&lt;/p&gt;
	&lt;p&gt;
&lt;/p&gt;
&lt;p&gt; &lt;small&gt; &lt;a href="http://powertech.blog.co.uk/2007/06/17/page_rank~2470650/#comments"&gt;Comments&lt;/a&gt; &lt;/small&gt; &lt;/p&gt;</content></entry><entry><id>tag:powertech.blog.co.uk,2007-06-17:/2007/06/17/title~2470594/</id><title>statics</title><link rel="alternate" type="text/html" href="http://powertech.blog.co.uk/2007/06/17/title~2470594/"/><author><name>powerzone</name></author><published>2007-06-17T20:14:28+02:00</published><updated>2007-06-17T20:16:31+02:00</updated><content type="html">	&lt;p&gt;&lt;a href="http://www.mypagerank.net"&gt;&lt;img src="http://www.mypagerank.net/services/seostats/seostats.php?s=d9490953bdfb71970acffc975e225b015e0b1f3fea&amp;bg=FFFFFF&amp;textcolor=000000&amp;bordercolor=999999&amp;indicatorcolor=5EAA5E&amp;ugo=1&amp;uho=1&amp;umo=1&amp;amo=1&amp;upr=1&amp;tuv=1&amp;tpv=1&amp;yuv=1&amp;ypv=1&amp;ttuv=1&amp;ttpv=1&amp;uonline=1&amp;f=49734" title="SEO Stats powered by MyPagerank.Net" border="0"&gt;&lt;/a&gt;
&lt;/p&gt;
&lt;p&gt; &lt;small&gt; &lt;a href="http://powertech.blog.co.uk/2007/06/17/title~2470594/#comments"&gt;Comments&lt;/a&gt; &lt;/small&gt; &lt;/p&gt;</content></entry><entry><id>tag:powertech.blog.co.uk,2007-06-17:/2007/06/17/moderatively_long_lines~2470411/</id><title>Moderatively long lines</title><link rel="alternate" type="text/html" href="http://powertech.blog.co.uk/2007/06/17/moderatively_long_lines~2470411/"/><author><name>powerzone</name></author><published>2007-06-17T19:48:30+02:00</published><updated>2007-06-17T20:57:04+02:00</updated><content type="html">	&lt;p&gt;&lt;strong&gt;&lt;u&gt;Morderately long lines:&lt;/u&gt;&lt;/strong&gt;&lt;/p&gt;
	&lt;p&gt;*Transmission lines between 80km and 240km can be assumed under this category.&lt;br&gt;
*These transmission lines represented by T or π.&lt;br&gt;
&lt;img src="http://data4.blog.de/media/771/1700771_2ad520975a_s.jpeg" alt="lastscan" vspace="5" hspace="5"&gt;&lt;/p&gt;
	&lt;p&gt;Vs=Sending end voltage for single phase&lt;br&gt;
Vr=Receiving end voltage for single phase&lt;br&gt;
Is=Sending end current&lt;br&gt;
Ir=Receiving end current for single phase&lt;br&gt;
Z=R+jX&lt;br&gt;
Y=G+jB&lt;br&gt;
G=leakage conductance per phase&lt;br&gt;
B=Capacitive susceptance&lt;/p&gt;
	&lt;p&gt;&lt;img src="http://data4.blog.de/media/792/1700792_0be3e124c5_s.jpeg" alt="lastscan2" vspace="5" hspace="5"&gt;&lt;/p&gt;
	&lt;p&gt;Normally moderately long lines leakage may also be ignored. Therefore Y=G+jB=jwc0&lt;br&gt;
W=Radian frequency of the power supply&lt;br&gt;
C0=Capacitance to neutral of the transmission line.&lt;/p&gt;
	&lt;p&gt;&lt;u&gt;&lt;strong&gt;Long lines:&lt;/strong&gt;&lt;/u&gt;&lt;br&gt;
*Te lines beyond 240km can be named as long lines.&lt;br&gt;
*In Sri lanka, long lines cannot be seen yet!&lt;br&gt;
*In long lines impedance &amp; admittance assumed uniformly distributed.  &lt;/p&gt;
&lt;p&gt; &lt;small&gt; &lt;a href="http://powertech.blog.co.uk/2007/06/17/moderatively_long_lines~2470411/#comments"&gt;Comments&lt;/a&gt; &lt;/small&gt; &lt;/p&gt;</content></entry><entry><id>tag:powertech.blog.co.uk,2007-06-17:/2007/06/17/introduction_to_power_systems~2469984/</id><title>Introduction to power systems</title><link rel="alternate" type="text/html" href="http://powertech.blog.co.uk/2007/06/17/introduction_to_power_systems~2469984/"/><author><name>powerzone</name></author><published>2007-06-17T18:35:20+02:00</published><updated>2007-06-17T18:35:20+02:00</updated><content type="html">	&lt;p&gt;&lt;strong&gt;&lt;u&gt;Electrical Power Systems&lt;/u&gt;&lt;/strong&gt;&lt;/p&gt;
	&lt;p&gt;Power system engineering is special branch of electrical engineering. Power engineering can be mostly touch with transmission, distribution &amp;technology.&lt;br&gt;
The special responsibility of a power system is that, in addition to maintain the generation of electrical power at adequate level, the power has to be transmitted to the various load levels.&lt;br&gt;
Power system engineer should have a knowledge regarding the operation &amp; control of inter connected power systems, specially when inter connecting the local grid to form an integrated power pool.&lt;br&gt;
Power engineering never falls down, because of energy crises all over the world. But lots of connecting problems , energy (voltage) converting problems , &amp; planning operation problems may occur in the field while working.&lt;br&gt;
There are three major classification in transmission lines.&lt;br&gt;
1.	Short lines&lt;br&gt;
2.	Moderately long lines&lt;br&gt;
3.	long lines&lt;/p&gt;
&lt;p&gt; &lt;small&gt; &lt;a href="http://powertech.blog.co.uk/2007/06/17/introduction_to_power_systems~2469984/#comments"&gt;Comments&lt;/a&gt; &lt;/small&gt; &lt;/p&gt;</content></entry></feed>